Capacity
The standard equipment model table shows the equipment capacity under the condition of 3bar pure steam pressure and 6bar industrial steam. The unit is kg/h. The actual capacity of the same type of equipment needs to be multiplied by the conversion factor according to the actual operating pressure to obtain the specified capacity.
model selection example
Industrial steam pressure: 7bar
Required pure steam pressure: 2bar
Maximum demand for pure steam 500kg/h
Conversion factor: 1.7
Specified output 500/1.7 = 294 kg/h
Selected model: PSG 300 DT5